Index of every page on this site: llms.txt
All skills
askie avatar

/grix-customer-mail

@78b3adc
by askieaskie/grix157 stars
7
Run it yourself

Locate a Grix customer from a Sentry alert or connector problem report and prepare a one-to-one fix-notification email. Use when asked to find which user owns a host (by host name, connector version, or upgrade report), draft a customer fix email, or notify users stuck on old grix-connector versions. One-to-one customer mail goes from the monitored support@grix.im mailbox by a human; the Aliyun DirectMail no-reply sender is reserved for verification codes and opt-in announcements and must not be used for one-to-one follow-ups.

  • 2 files
  • 10.4 KB
  • Updated last month
  • GitHub
Use this Skill: https://skilld.dev/gh/askie/grix/grix-customer-mail

Nothing lands on disk. Nothing to clean up.

Fork this Skill

Edit a local copy. It keeps the author and licence.

templates.md

≈958 tokens on demand. Your agent reads this file only when SKILL.md points to it.

Customer fix email templates

Replace every <...> placeholder from the resolved user evidence before handing off. Both templates assume sending from support@grix.im, so the customer can reply directly — keep that line accurate.

1. Windows: connector startup crash (spawn wmic ENOENT, 3.x)

Subject: 【需您操作】Grix 连接器在 Windows 上无法启动的修复办法(约 3 分钟)

您好:

我们监测到您电脑 <HOST> 上的 Grix 连接器(版本 <VERSION>)近期反复启动失败,您本机的 <N> 个智能体(<AGENT NAMES>)目前处于离线状态。

原因: 微软在新版 Windows 11 中移除了一款名为 wmic 的系统组件,旧版连接器启动时依赖它,导致每次启动即失败。新版连接器已改用 Windows 现代接口,不再依赖该组件,手动升级一次即可彻底修复。

请按以下步骤操作(约 3 分钟):

  1. 在该电脑上打开 PowerShell(开始菜单搜索 PowerShell 即可,不需要管理员权限);
  2. 先停止当前反复重启的旧服务:grix-connector stop
  3. 安装最新版:npm install -g grix-connector@latest
  4. 用新版重新铺设并启动服务(必须用 restart,不要用 start,只有 restart 会把旧版在 Windows 上的运行副本一并更新):grix-connector restart
  5. 等待约 1 分钟,打开 Grix 桌面端或手机端,确认上述智能体恢复「在线」。

如果提示 npm 或 grix-connector 不是可识别的命令,请不要自行安装其他软件,直接回复本邮件,我们会协助处理。

如果升级后仍未上线,请按 Win+R 输入 %LOCALAPPDATA%\grix-connector\logs,把最新文件夹内的 daemon.err.log 作为附件回复本邮件,并附上执行命令时终端的报错截图,我们会继续跟进。

给您带来的不便我们深表歉意。升级完成后,该问题不会再随 Windows 更新复发。

Grix 技术支持团队 <DATE>

Notes for the drafter:

  • The restart (not start) instruction is the crux: 3.x Windows services execute from a runtime copy, and only restart re-lays it. Machines whose automatic upgrade was rolled_back with STARTUP_CRASH are exactly this.
  • Temporary workaround, only if the user cannot upgrade immediately: an administrator may restore wmic with DISM /Online /Add-Capability /CapabilityName:WMIC~~~~. Do not lead with it.

2. macOS: empty-config loop (No config files found in ~/.grix/config)

Subject: 【需您操作】Grix 连接器因缺少配置文件反复报错的处理办法

您好:

我们监测到您的 Mac(<HOST>)上有一个 Grix 连接器在反复报错:它所在的 ~/.grix/config 目录下没有任何智能体配置文件。该程序没有任何智能体在运行,不影响您其他工作,但会持续产生错误报告。请二选一处理:

  1. 仍在使用 Grix:在终端执行 npm install -g grix-connector@latest 后,按应用内指引重新配置智能体即可;
  2. 已不再使用:在终端执行 npm uninstall -g grix-connector 卸载,并在「系统设置 → 通用 → 登录项」中移除相关启动项,让它彻底停下来。

如不确定它是如何装上的,直接回复本邮件,我们可以协助确认。

Grix 技术支持团队 <DATE>

Notes for the drafter:

  • This condition means no agents were ever configured (or the config was deleted) while autostart remained; current versions idle instead of crashing, so any machine still reporting it runs pre-fix code or a stale install entry.
  • A host with no platform record at all cannot be matched to an account from the production database; expect to reach this user out-of-band or not at all, and say so in the handoff.

Source: SKILL.md on GitHub

No rule matched.

skilld matched fixed text patterns in SKILL.md and file names. Patterns miss obfuscated code.

skilld run checks every file with the same patterns. It asks for approval before it loads a Skill with a behavior marked Needs approval.

No third-party reports yet.

Signed by skilld at 78b3adc. This ties the file your Agent reads to that commit on GitHub. It does not review the instructions.

Last checked against GitHub yesterday.

Activeupdated last month

README badge

README badge for askie/grix/grix-customer-mail