CoreWeave Fabric Diagnostics
Community-contributed. Not affiliated with, endorsed by, or sponsored by CoreWeave, Inc. CoreWeave is a registered trademark of CoreWeave, Inc.
Overview
Review positive NCCL transport evidence without guessing a slowdown or billing impact. The offline script distinguishes an InfiniBand transport selection from positive GPU Direct RDMA evidence. A warning mentioning NET/IB, a bootstrap socket or an isolated bandwidth figure cannot establish a healthy data path. Use Read for supplied diagnostics, Glob for owner-selected rank logs, Write the report and Edit the proposed local correction; do not mutate the cluster.
Prerequisites
- Sanitized NCCL_DEBUG=INFO output from one known run, with rank/time identity preserved.
- Optional admitted Pod resource blocks and ibstat output from the same scope; Pod YAML may contain secrets and must be reviewed before sharing.
- Python 3 and the pinned PyYAML dependency from
scripts/requirements.txt, installed in a local isolated environment. - Owner authorization before any cluster query, rerun, benchmark or resource change; those may access data or spend compute.
Instructions
- Separate runs and ranks. Read
references/nccl-debug-reading.mdto distinguish bootstrap, transport selection, warnings and GDR evidence. - Run the bundled checker on the supplied diagnostic file. Treat
unknownas missing evidence andmixedas requiring rank/run correlation, not a guaranteed broken fabric. - Review each communicating container’s resource block independently.
rdma/ib: 1in limits can supply an omitted request through Kubernetes defaulting; an explicit request must match. Requests-only, zero and mismatched values need correction. - Confirm the Node Pool supports InfiniBand, the image has the appropriate NCCL/OFED userspace, and effective environment settings match the current platform guidance. A missing environment line in a paste does not prove the variable is unset.
- Have the platform owner review the proposed manifest change, then collect fresh evidence from the same workload. Do not install host drivers, reset GPUs or override managed health cordons.
- Compare busbw with an equivalent measured baseline including topology, GPU count, image, driver/NCCL versions and message size. No fixed speedup, slowdown or dollar saving is inferred.
Examples
python3 "${CLAUDE_SKILL_DIR}/scripts/fabric-check.py" --in diagnostics.txt --json
python3 "${CLAUDE_SKILL_DIR}/scripts/fabric-check.py" --self-testFor an owner-approved read of the exact Pod, use an explicit context and namespace, and review its output before retaining it:
kubectl --context="$CW_CONTEXT" --namespace="$CW_NAMESPACE" get "pod/$CW_POD" -o yamlA positive Using network IB observation sets transport to IB; without a GDR marker, gpu_direct_rdma_confirmed stays false.
The compatibility field rdma_engaged describes the observed transport category, not complete fabric health or GPU-direct verification. It is not-applicable for a single-node run (nNodes 1, or only P2P/SHM channels), where no traffic crosses the network.
On NCCL 2.22 and newer, TCP fallback prints NET/IB : No device found. and then NET/IB : Using [RO]; OOB <if> with an empty device list. IB counts only when a real [n]device:port/IB or /RoCE entry appears, so that run reads as Socket. External IBext/IBext_vN plugins count as IB, and log lines are read even when the NCCL INFO prefix was lost in pasting.
Output
- Transport, separate GDR evidence, resource findings and port observations.
- Observed bandwidth labeled unverified against a baseline, with no invented pass/fail threshold.
- A bounded proposed next step and explicit incomplete evidence; no automatic cluster action.
Error Handling
| Observation | Response |
|---|---|
| Only an IB failure warning | Transport remains unknown; obtain positive selection/data-path evidence. |
| Limits-only rdma/ib: 1 | Accept request defaulting; investigate the effective Pod and transport instead of demanding duplicate YAML. |
| Multiple container blocks | Review each independently; do not combine a sidecar request with another container’s limit. |
| Inactive/Down port | Report the port observation to the platform owner; it does not establish the root cause of every Node event. |
| No complete log | Preserve unknown; a keyword count is not proof of success. |
Resources
- Resource and device checks
- NCCL evidence interpretation
- Bandwidth comparison
- CoreWeave RDMA guidance
Evidence status
Deterministic offline fixtures cover parsing and refusal cases. No live NCCL, GPU benchmark or CoreWeave account was used for this package review.