Use this skill when the user is operating the DOCA Firefly Service container on BlueField — picking the four PTP configuration axes (role / profile / domain / interface), wiring the BlueField PHC + host follower + consumer workload pairing, deciding whether PTP-grade time is even needed (vs. chrony / NTP), or debugging a Firefly deployment where PTP isn't syncing or the host clock isn't following. Trigger even when the user does not explicitly mention "DOCA Firefly" or "PTP" — typical implicit phrasings include "container green but PTP never advances past LISTENING", "Firefly says synced but the host clock still drifts", "sync acquired but offset is tens of microseconds", "my Rivermax SMPTE workload needs PTP", or "is chrony good enough". Refuse and route elsewhere for installing DOCA, host-side chrony / ptp4l config bodies, PTP topology / boundary-clock design, building DOCA apps that read the disciplined PHC, or other DOCA services (DMS, Flow-Inspector, HBN) — those belong to other skills.

Use this Skill: https://skilld.dev/gh/nvidia/skills/doca-firefly

This session only. Nothing lands on disk.

TASKS.md

≈6.8k tokens on demand. Your agent reads this file only when SKILL.md points to it.

DOCA Firefly Service — Tasks

Where to start: The order is configure → build → modify → run → test → debug. The ## test verb is an iterative loop, not a one-shot pass — see the eval-loop overlay in ## test below. For Firefly, build and modify are about deployment configuration (container image selection, mounted config file, host-follower wiring), not about compiling source.

These verbs cover the in-scope Firefly operational workflows for an external operator deploying the Firefly container on BlueField. Every step assumes the operator has consulted the live public DOCA Firefly Service Guide (reachable through doca-public-knowledge-map ## DOCA services) and is using it as the authoritative reference; this file prescribes the order and what to look up where, not a copy-paste runbook.

configure

Preparing the BlueField, picking the four PTP axes, and wiring the end-to-end discipline before the container starts.

  1. Confirm Firefly is actually the right answer. Per the path-selection rule in CAPABILITIES.md ## Safety policy:
    • Is PTP-grade time precision genuinely required by the consumer workload (SMPTE ST 2110 on Rivermax, 5G UPF, financial trading, or sub-microsecond distributed-database time)?
    • Is the network between Firefly and the upstream PTP master PTP-aware (PTP-aware switches in the path, or boundary clocks where the switches are not PTP-aware)?
    • If either answer is no, stop here and tell the user honestly: keep the host's chrony / NTP setup, do not deploy Firefly speculatively.
  2. Confirm the env is healthy. This skill expects DOCA to be installed on the BlueField. If that has not been verified, run doca-setup ## test first. If the user has no install yet, route to doca-setup ## no-install for the public NGC DOCA container path.
  3. Decide the four PTP configuration axes. Per the four-axis table in CAPABILITIES.md ## Capabilities and modes, commit before starting the container to:
    • Role — master / slave / boundary clock / transparent clock. Drives whether Firefly follows or sources time on the segment.
    • Profile — the PROFILE env var accepts EXACTLY default / media / telco-l2 / custom (per services/firefly/doca_firefly.yaml). These four values map onto the industry-standard PTP profile names: default → IEEE 1588 default; media → SMPTE 2059-2 (broadcast); telco-l2 → G.8275.1 only (telecom full timing over L2; ptp4l-telco-l2.conf extends G.8275.1.cfg); custom → the user's own config file (e.g. G.8275.2 partial timing corresponds to the separate telco-l3 config, which is NOT an accepted PROFILE value and is reached only via custom). Do NOT put the industry-standard names directly into the env var — they are not accepted values. Must match (or interop with) the upstream master's profile.
    • Domain number — must match the upstream master's domain; mismatched domains = zero peers visible.
    • Network interface — typically the wire-side BlueField port, not the management port. The port must have hardware PTP timestamping enabled.
    • Plus the transport choice (L2 multicast / L3 unicast / L3 multicast) per the upstream topology.
  4. Plan the host-side follower. Decide which mechanism the host will use to read the BlueField PHC — chrony with the PHC source, or ptp4l / phc2sys reading the PHC. Without this step the host clock does NOT follow the Firefly-disciplined PHC, no matter how cleanly the container comes up. Capture the device path the host will read (/dev/ptpN) and the follower's config intent; the body of the host-side config file is the host operator's responsibility and lives in upstream Linux PTP / chrony docs, not in Firefly.
  5. Plan the consumer workload pairing. If the deployment exists to support a Rivermax SMPTE workload, the Rivermax-side precondition matrix (Rivermax SDK + license + scheduling discipline) is ALSO required — route the Rivermax side to doca-rmax ## configure. For 5G UPF / finance / distributed databases, the consumer-side wiring is owned by the workload's own docs; Firefly's job is to keep the disciplined time available.
  6. Author the Firefly container config. From the public DOCA Firefly Service Guide, derive the config file fragment for the chosen role / profile / domain / interface / transport. Quote config keys from the live guide, do NOT infer them from generic ptp4l knowledge. Plan where the config file will live on the BlueField filesystem and what mount path the container expects. Also inventory the effective state and config source for all six shipped subsystems — PTP, PTP Monitor, PHC2SYS, PPS, SyncE, and Firefly Servo — using the version-matched doca_firefly.yaml. Do not assume that choosing the four primary PTP axes configures every subsystem the deployment needs.

build

Firefly is a service shipped as a container, not a library. There is no Firefly application artifact for the operator to build — the container ships from NGC and the config is a static file.

If the user is asking how to build a PTP client in their own language (e.g. an application that reads the disciplined system clock with sub-microsecond precision), that is not a Firefly question:

  • For applications that read the BlueField PHC directly via a DOCA library (e.g. a Rivermax-based SMPTE workload), the build is the DOCA library's build — route to doca-programming-guide and the matching libs/<library> skill (e.g. doca-rmax for SMPTE).
  • For applications that read the OS system clock that the host-side follower is disciplining, no DOCA-specific build is needed — the application uses standard clock_gettime(2) against the appropriate clock, and the precision is whatever the host-side follower delivers. The follower setup is upstream Linux PTP / chrony, not Firefly.

If the user is instead asking how to build the Firefly container itself from source, that is not an external-operator workflow — the container ships pre-built from NGC and rebuilding it is out of scope for this skill. Route to the public DOCA Firefly Service Guide via doca-public-knowledge-map ## DOCA services.

modify

Firefly does not have a "modify a sample" workflow analogous to DOCA libraries; there is no Firefly sample program a user starts from. The Firefly analog of "modify" is adapt the documented container config recipe to the user's environment:

  1. Start from the documented recipe. Identify the public guide's recipe that matches the user's PTP role and profile. Quote it; do not author a new one from scratch.
  2. Diff against the user's environment. Note the specific substitutions the user must make: interface name, domain number, transport choice, upstream master address (for slave / boundary roles), config file path, container image tag (always pulled from NGC per the public guide).
  3. Apply minimum-change. Change only what the user's environment forces. Every additional deviation from the documented recipe widens the surface for an unintended PTP mismatch the operator will have to debug later.
  4. Re-validate against the four-axis table. Each substitution is a chance to accidentally break one of the four PTP axes (role / profile / domain / interface). Walk CAPABILITIES.md ## Capabilities and modes one row at a time after every substitution.
  5. Re-validate against the END-TO-END discipline. Per the END-TO-END rule in CAPABILITIES.md ## Safety policy, any change that affects which PHC device the host reads, or which port carries PTP, also affects the host-side follower's config. Update both together.

The agent's anti-pattern alert: a "start from a generic ptp4l config and adapt" is almost always slower than starting from the public Firefly Service Guide's recipe, because the Firefly config schema is documented per the public guide and is not 1:1 with upstream linuxptp.

run

Bringing up the Firefly container and confirming PTP advances through its state machine, with the host follower attached, BEFORE layering any consumer workload on top.

Before pulling or starting the image, confirm the operator can pull images, run containers, and mount the Firefly config on BlueField Arm under the runtime named by the public Container Deployment Guide. If not, stop and hand off to the BlueField container-runtime owner.

  1. Pull the Firefly container image from NGC at the tag the public Firefly Service Guide names for the operator's DOCA release. Quote the tag from the live guide; do NOT memorize or invent the tag. If that version-matched guide/tag source is inaccessible, stop and ask the operator to provide the tag from the guide; do not infer one from the host package version.
  2. Start the container per the public Container Deployment Guide pattern. Mount the Firefly config file at the path the public Firefly Service Guide names. The runtime command shape (e.g. docker run / crictl / BlueField container manager) is documented in the Container Deployment Guide reachable through doca-public-knowledge-map ## DOCA services.
  3. Confirm the container is running, not restart-looping. A restart loop is a layer-1 symptom per CAPABILITIES.md ## Error taxonomy (container runtime / image tag / config mount); diagnose it before touching PTP config.
  4. Watch the Firefly container's logs for the PTP state-machine transitions. The container's stdout is the primary observability surface. The PTP state should advance from LISTENING through UNCALIBRATED and into SLAVE (for slave role) or MASTER (for master role) within the timeline the public guide describes for the chosen profile. For a boundary clock, inspect every configured PTP port and verify the documented upstream-facing and downstream-facing conditions; a single aggregate SLAVE or MASTER observation is insufficient. For a transparent clock, verify the version-matched guide's documented forwarding and residence-time-correction condition rather than requiring a slave/master terminal state.
  5. Confirm the BlueField PHC is being disciplined. The PHC offset (relative to its master) and frequency adjustment are the numeric proof. Use the upstream PTP tooling (e.g. pmc, phc_ctl) the public guide cites; do not invent commands.
  6. Wire the host-side follower NOW. Per the host-follower step in ## configure, start chrony with the PHC source or ptp4l / phc2sys reading the PHC. Confirm chronyc tracking (or pmc against the host's PTP daemon) reports the BlueField PHC as the reference and a tight offset. Without this step the host clock does NOT follow the PHC.
  7. Single-event smoke (next: ## test step 1). Before driving any consumer workload, walk ## test step 1 once to confirm end-to-end discipline holds; only then layer the consumer workload on top.

For the runtime version + container-tag cross-checks that underlie "my Firefly behaves differently from what the docs say", see doca-version TASKS.md ## run and apply the container-tag-lags-host-package overlay from CAPABILITIES.md ## Version compatibility.

test

Firefly has no "compile and unit-test" workflow — testing is operational and end-to-end.

## test is an iterative loop, not a one-shot pass. Every mutation (role change, profile change, domain change, interface change, transport change, host-follower change) re-opens the smoke sweep. Skipping the re-run after a mutation is the failure mode this loop replaces.

The eval-loop overlay (rows apply to every Firefly deployment, not just one PTP profile):

Step Why this is a loop, not a step Where the substance lives
1 → 4 → 1 Step 4 (consumer-workload check) often reveals an as-deployed gap in the host-follower or in the Firefly config; loop back to step 1 ## test step 4
2 → ## debug When the four-axis smoke does NOT progress past LISTENING, the deployment is non-functional — escalate to ## debug layer 2 immediately, do not run later steps ## debug
3 → ## configure → 3 When the host follower does not track the PHC, the host-side config is wrong — loop back to ## configure step 4 and re-run ## configure
1..5 → ## run Each loop iteration ends with a smoke; if all five pass, hand off to live ## run traffic ## run

The agent's rule: every mutation re-opens the sweep. A configuration change followed by "it probably still works" is exactly the failure mode the iterative loop is here to prevent.

  1. End-to-end smoke. With Firefly running and the host follower wired, confirm in this order: (a) Firefly container stdout shows PTP advanced to SLAVE or MASTER per the chosen role; (b) PHC offset reported by pmc / phc_ctl is within the profile's expected range; (c) host-side follower reports the PHC as its reference with a tight offset; (d) the host's date / clock_gettime(CLOCK_REALTIME) agrees with an independent source within the profile's spec.
  2. Four-axis smoke. Passively compare the effective role, profile, domain, interface, and transport with the upstream peer; confirm captured PTP traffic and peer state agree. Do not mutate a live timing domain merely to prove the mismatch path.
  3. Host-follower smoke. Confirm the follower names the BlueField PHC as its source and that its offset changes in step with the PHC observations. This is the required live/shared-system check.
  4. Consumer-workload smoke. For Rivermax SMPTE, run the doca-rmax single-frame smoke (per doca-rmax TASKS.md ## test) with the disciplined PHC available; for 5G UPF / finance / distributed databases, the workload-side smoke is the workload's own concern. The Firefly contribution to the consumer smoke is "the disciplined time was actually available when the workload asked for it" — chronyc tracking snapshot at the time of the smoke is the evidence.
  5. Capability snapshot. Save the as-deployed answer to: which Firefly container tag is running, which role / profile / domain / interface / transport are in effect, which follower mechanism the host is using, what the steady-state PHC offset looks like. This snapshot is the artifact that lets future debug sessions skip rediscovery.

Optional disruptive negative checks — excluded from the required green sweep. Run these only on isolated test resources or in an operator-approved maintenance window with rollback ready:

  • Temporarily select a domain the upstream master is not using, confirm peering fails, then restore and re-run the required sweep.
  • Stop the host follower, confirm loss of discipline, restart it, and re-run the required sweep.

On live or shared systems, skip both and record the passive evidence from required steps 2–3 instead.

debug

Layered diagnosis. Walk the layers in this order; do not skip down without clearing the layer above. The five layers match CAPABILITIES.md ## Error taxonomy.

  1. Container runtime layer. Is the Firefly container actually running and not restart-looping? Symptoms: container exits immediately, image pull fails, restart count climbing. Resolution: confirm the image tag matches what the public guide names for the operator's DOCA release; confirm the config mount path matches what the public guide names; confirm BlueField has the runtime configured per the public Container Deployment Guide. This layer is owned by the container runtime, not by PTP.
  2. Four-axis PTP-config layer. Container green; PTP never advances past LISTENING, or no peers seen on the wire, or the wrong upstream master is selected. Resolution: walk the four-axis table in CAPABILITIES.md ## Capabilities and modes one row at a time, comparing the Firefly config against what the upstream master / network actually presents. tcpdump for PTP traffic on the configured interface is the cheapest confirmation of which axis is wrong; defer to upstream Linux PTP / tcpdump docs for the exact filter.
  3. Host-follower layer. PTP locks (Firefly says synced; PHC offset is tight); host OS clock drifts. Resolution: the host-side chrony / ptp4l / phc2sys is not configured to follow the PHC, OR it is configured but a competing NTP / chrony source is winning. Walk chronyc tracking, chronyc sources, and (if ptp4l is the follower) pmc against the host's PTP daemon. This layer is owned by upstream Linux PTP / chrony, not by Firefly — Firefly is correct.
  4. PTP-aware-path layer. PTP locks; sync acquired; offset and jitter wildly past the profile's spec. Resolution: a non-PTP- aware switch in the path is silently adding variable latency that PTP cannot correct from the endpoint. Confirm via the network team / switch-side inspection. The fix is on the network side: insert boundary clocks at the non-PTP-aware switch, or replace the switch with a PTP-aware one. Do NOT try to fix this from Firefly config; it is a network-path property, not a Firefly knob.
  5. Consumer-workload layer. Firefly correct; PHC correct; host clock follows PHC; but the consumer workload still reports time drift. Resolution: the workload is reading its own time source instead of the disciplined system clock. For Rivermax, walk doca-rmax TASKS.md ## debug; for 5G UPF / finance / distributed DB, the workload's own docs.
  6. Version layer. When the public Firefly Service Guide page appears to disagree with what the deployed container does, the docs version may not match the container tag. Walk doca-version TASKS.md ## debug layer 2 (partial install / version mismatch) and apply the container-tag overlay from CAPABILITIES.md ## Version compatibility.
  7. Cross-cutting layer. For env-side and program-side debug that is not Firefly-specific (host install, host kernel, DOCA library errors Firefly may surface), drop to doca-debug TASKS.md ## debug.

When a diagnosed root cause belongs to the host follower, network path, consumer workload, version alignment, or another cross-cutting owner, hand it off and stop iterating on Firefly configuration.

Command appendix

Firefly-specific commands the verbs above reach for, grouped by purpose so the agent picks the right family without searching prose. Every row is a class — the agent must not invent flags beyond what the row names; flag and command discovery is --help on the installed tool or the public guide, not prose recall.

Infra-aware preamble (every row below). Per the bundle's detect → prefer → fall back → report contract documented in doca-structured-tools-contract ## The agent behavior contract, the agent should:

  1. Probe for the matching structured helper FIRST (doca-env --json for version + devices + libraries + drivers + hugepages in one shot; the BlueField container manager's structured status output when available).
  2. If the probe succeeds, the structured tool's output is the authoritative answer and the agent SHOULD NOT also run the manual command in the row below. Report "using structured <tool>".
  3. If the probe fails, fall back to the manual command in the row. Report "falling back to manual chain".
  4. The schemas the structured tools emit are defined in doca-structured-tools-contract ## Schemas; the version-handling semantics (four-way match, NGC, headers-win) are owned by doca-version.
Purpose Command (class shape) Owning step Reads as healthy when …
Container lifecycle The BlueField container manager's start / stop / status command for the Firefly container, per the public Container Deployment Guide ## run Container running, restart count stable.
Container logs The BlueField container manager's log-stream command for the Firefly container ## debug layer 1 + 2 PTP state-machine transitions visible; no documented error / warning lines repeating.
PHC offset / frequency pmc -u -b 0 'GET CURRENT_DATA_SET' or phc_ctl /dev/ptpN get (upstream Linux PTP tooling — quote the exact form from the public Firefly guide) ## run step 5; ## debug layer 2 Offset within the chosen profile's spec; frequency adjustment converged.
Ports-state inspection pmc -u -b 0 'GET PORT_DATA_SET' (upstream Linux PTP) ## debug layer 2 Slave/master roles reach their documented state; boundary-clock validation covers every configured upstream/downstream PTP port; transparent-clock validation uses the guide's documented forwarding and residence-time-correction condition rather than a slave/master terminal state.
On-the-wire confirmation tcpdump for PTP traffic on the configured interface (upstream Linux / tcpdump — defer to its own docs for the exact filter) ## debug layer 2 PTP frames egress / ingress as the role expects; domain numbers in the frames match the configured domain.
Host-follower status (chrony) chronyc tracking and chronyc sources (upstream chrony) ## run step 6; ## debug layer 3 Reference ID corresponds to the PHC; offset tight; stratum / leap status sane.
Host-follower status (ptp4l) pmc against the host-side PTP daemon (upstream Linux PTP) ## run step 6; ## debug layer 3 Host's PTP daemon reports the PHC as its source; offset tight.
Container tag in use The BlueField container manager's image-inspect command for the running Firefly container ## run step 1; ## debug layer 6 Tag matches what the public Firefly Service Guide names for the operator's DOCA release.

Three cross-cutting rules for this appendix:

  • Never invent a Firefly config key, container tag, or PTP command. The public Firefly Service Guide is the contract; upstream Linux PTP / chrony / tcpdump docs are the secondary source for the cross-cutting PTP tools the guide reuses. Prose- derived flags are the most common hallucination failure for this skill.
  • Container before PTP. When triaging, confirm the container layer (running, not restart-looping, image tag correct) before reading any PTP-layer command. A non-running container makes every PTP-layer command meaningless.
  • Cross-link instead of duplicate. Cross-cutting env commands (port-state, devlink, ip link, ethtool) live in doca-setup TASKS.md ## Command appendix; this appendix names only the Firefly-specific ones.

Deferred task verbs

  • Installing DOCA on the BlueField — out of scope here. Route to doca-setup ## configure for env preparation and doca-setup ## test for install health verification, or doca-setup ## no-install for the public NGC DOCA container path.
  • Installing or configuring the host-side time-sync follower (chrony / ptp4l / phc2sys) — out of scope here. The Firefly contract is that the host must be configured to follow the PHC; the follower's own config body is upstream Linux PTP / chrony documentation, not a Firefly concern.
  • Designing the PTP topology (where to place boundary clocks, which switches must be PTP-aware, redundant masters, BMCA configuration) — out of scope here. That is a network-side / topology-side concern that the operator owns; Firefly only consumes the topology decision.
  • Building a custom DOCA application that reads the disciplined PHC — not a Firefly question. Route to doca-programming-guide ## build for the canonical build pattern and the matching libs/<library> skill (e.g. doca-rmax ## configure for SMPTE) for the API surface.
  • Other DOCA services (DMS, DTS, BlueMan, Flow-Inspector, HBN, Argus, …) — not Firefly. Route to doca-public-knowledge-map ## DOCA services for the routing table and the matching services/<service> skill when it exists (e.g. doca-dms ## configure for device management). The container-shaped deployment pattern is shared; the per-service domain is different.

Cross-cutting

  • The public DOCA Firefly Service Guide is the single source of truth. Any config key, profile name, role name, container tag, or observability output the agent quotes must come from there, not from generic ptp4l / linuxptp / chrony knowledge.
  • PTP is END-TO-END. The Firefly container disciplines the BlueField PHC; the host-side follower disciplines the host clock from the PHC; the consumer workload reads the disciplined time. All three legs are mandatory; naming only one is how end-to-end discipline silently breaks.
  • Path-selection is mandatory up front. Firefly is the wrong answer when chrony / NTP suffices, when no PTP-aware path exists, or when pure software-side time precision is enough.
  • Smoke before scale. Every consumer workload (Rivermax, 5G UPF, finance, distributed DB) goes after the end-to-end smoke passes, never before.
  • For URL routing to the Firefly guide and other public DOCA documentation, see doca-public-knowledge-map ## DOCA services.

Source: SKILL.md on GitHub

No alerts2mo3 checks · Risk SAFE
  • Gen Agent Trust Hub2mo

    The doca-firefly skill is an operational guidance package for deploying and managing the NVIDIA DOCA Firefly Service container on BlueField devices. It provides detailed instructions on PTP configuration axes, host-side synchronization, and troubleshooting common deployment issues. No malicious patterns, obfuscation, or unauthorized data access were detected.

  • Socket2mo

    No alerts

  • Snyk2mo

    Risk: LOW · No issues

Signed by skilld at a5736e4. This ties the file your Agent reads to that commit on GitHub. It does not review the instructions.

Last checked against GitHub yesterday.

Activeupdated 2 months ago
metadata
{
  "kind": "service"
}
Other metadata
compatibility
BlueField-Arm-only DOCA service container; pulled from NVIDIA NGC and started under the BlueField OS container runtime. Host-side install is irrelevant. Requires a reachable PTP master (or runs as the master itself) and a PTP-aware network path; the host-side time follower (chrony / ptp4l / phc2sys reading the BlueField PHC) is also operator-owned.

README badge

README badge for nvidia/skills/doca-firefly